Camp Room Overview
1. The boundary dimension of the residential house: (length×width×height) 8000*2500*2570mm (the interior net storey height is 2200mm)
2. The boundary dimension of laundry, kitchen and dining hall: (length×width×height)10000*2500*2570(the interior net storey height is 2200mm)
3. The main longeron and main beam of the residential house are made of No. 20 channel steel, the frame No. 14 channel steel and the secondary beam No. 10 channel steel. The base is welded with hot rolled sheet steel as thick as 3mm, supported by wooden stick in the middle part and covered with woodboard, on which laid Senda laminate flooring, with a layer of water-proof isolation foam in between.
4. In laundry, kitchen and dining hall, the the main longeron and main beam at the base are made of No. 20 channel steel, the frame No.14 channel steel, secondary beam No.10 channel steel and the base is welded with hot rolled sheet steel as thick as 3mm, covered with concrete, on which is laid skid-resistant tiles.
5. The frames of platfond is constructed by δ14 channel steel in order to increase their rigidity, the ceiling is constructed by quarter bend with dimensions as 50*30*4, the external layer of it is made by hot rolled sheet steel as thick as 3mm and internal layer, i.e. ceilings is decorated by double flame-retardant sandwich composite board as thick as 50mm.
6. The four main pillars are made of square tubes with dimensions as 100*100*5mm, the external wall is constructed by corrugated board made from cold rolled sheet as thick as 2.5mm and the surface of internal wall is decorated by double flame-retardant sandwich composite board as thick as 50mm.
The indoor facilities
Please see more in the attached lists 1-5 and pics 1-5
The electricity supply indoors
The electricity is connected into camps by industrial staple-lock couplings so that supply power for the rooms, air-cons and temporary lights. Besides, the power supply is quite safe and reliable due to installation of the built-in electric circuit and laying of PVC pipes between corrugated board and laminboard.
Surface processing and painting craftsmanship
The electricity is connected into camps by industrial staple-lock couplings so that supply power for the rooms, air-cons and temporary lights. Besides, the power supply is quite safe and reliable due to installation of the built-in electric circuit and laying of PVC pipes between corrugated board and laminboard.
Surface processing and painting craftsmanship